Range of measurements of the propagation of ultrasonic vibrations, µs
10 … 9999
The measurement resolution of the propagation time of ultrasonic vibration, µs
0.1
Operating frequency of the ultrasonic oscillations, kHz
20-400
Base surface sounding measurements in mm
150
Output voltage, V
up to 100 to 1200
Standard EN 12504-4 and ASTM C597
Main applications
Standard UPV measurement with incorporated oscilloscope. Conforming to EN 12504-4 and ASTM C597. Also suitable for determining the Dynamic Modulus of Elasticity. The meter features a very accurate measurement of the transit time.
Measurement of the Attenuation of the Transmitted Energy. Very often the transit time only is not enough to identify dis-homogeneities and little damages as for example micro cracking of concrete which are, on the contrary, well located with this technique by properly processing the acquired waveforms.
Frequency Spectrum Analysis by FFT Method (Fast Fourier Transform-Algorythm). For determining the natural frequency of the ultrasonic pulse transmitted through the material. This determination is suitable for the examination of the pulse path and gives indications about possible cavities, delaminations, multi-layer elements or other similar dis-homogeneities.
Concrete Strength Evaluation combining the Rebound number and the UPV transit time. It is possible to use our digital test hammer to obtain the avarage value of rebound number. This value can be insert in the dedicated menu of UPV tester combining a typical surface measurement with the deeper UPV transit time in order to obtain a more reliable and extended information.
Other applications. To identify and evaluate Crack depth, Honey combing, Injection quality.
Payment & Shipping Terms:
Minimum Order Quantity: 1 pc
Price: 2000-6000 USD